Ambient imaging sources operate at atmospheric pressure: DESI uses charged droplets that impact the surface for desorption and ionization; LDPI excites the sample with a laser and then ionizes the neutral desorbed species photochemically; DPI combines electrospray with photoionization in a synergistic manner; AP-MALDI moves the matrix-assisted desorption of conventional MALDI to ambient pressure. Their common feature is that the sample need not enter vacuum, so colored, aqueous or large-volume samples can be analyzed directly.
By eliminating vacuum pumping and complex sample transfer, ambient sources have structural advantages in sample throughput, operational convenience, and in-vivo/near-in-situ research. The trade-off is the need to control air background and humidity, and to efficiently introduce ambient ions into the mass analyzer through an interface.
Compared with vacuum MALDI/SIMS, which require frozen sections, conductive slides and spraying, the ambient matrix-free route (LDPI/DPI) usually only requires placing the sample on a positioning stage and calibrating coordinates, significantly reducing the preparation steps, and is especially suitable for time-sensitive scenarios such as clinical rapid sections, in-situ analysis of medicinal materials, and forensic evidence.
In application, ambient sources excel at the tissue distribution of metabolites, lipids, drugs and their metabolites; for macromolecules such as proteins/peptides, matrix or higher-vacuum strategies are still required. Choosing ambient or vacuum essentially comes down to a trade-off between simplified sample preparation and macromolecule coverage or clean background.
Neo-Source MSI LDPI is an ambient, matrix-free, laser/photoionization imaging source with a spatial resolution of 2–3 μm (among the leading in the industry), a low background above m/z≥70, and is suitable for imaging small-molecule drugs and metabolites; MSI DPI uses electrospray plus photoionization to achieve no polarity bias, with a nominal sensitivity 1–4 orders of magnitude higher than DESI, covering tissue-scale imaging of 20–200 μm.
Both adopt an external modular design compatible with mainstream mass spectrometers such as Agilent, SCIEX and Thermo, allowing users to gain ambient matrix-free imaging capability while retaining their original instrument investment.
Matrix-free:No organic matrix spraying required; m/z>=70 low background, well suited to small-molecule drugs and metabolites
Ambient operation:Works in open ambient environment; simplified sample preparation; supports near in-situ / in-vivo analysis
Resolution:2-3 um spatial resolution, among the leading in the industry, reaching single-cell / subcellular scale
Modular compatibility:External add-on design; model-by-model compatibility with Agilent / SCIEX / Thermo mainstream MS hosts
To obtain detailed specifications, compatible models, or a quotation for the MSI LDPI / DPI full series imaging ion sources, visit the Neo-Source official website, or contact the official team for compatibility advice tailored to your mass spectrometer (Agilent / SCIEX / Thermo and other mainstream MS).