Product · Neo-Source

External mass spectrometry imaging ion sources compatible with Orbitrap

Thermo Orbitrap is known for high resolution and ppm-level mass accuracy, and is an important platform for spatial metabolomics and lipidomics. Through an external imaging ion source (such as Neo-Source LDPI/DPI), Orbitrap users can expand spatial imaging while retaining high-resolution analysis capability, obtaining a combination of accurate mass plus spatial coordinates.
Table of Contents
1. Compatibility foundation of the Orbitrap platform2. Technical requirements for external sources3. Synergistic value of Neo-Source LDPI/DPI4. Selection and acceptance suggestions
Neo-Source imaging source: modular external add-on, compatible with mainstream MS Neo-Source External mass spectrometry imaging ion sources compatible with Orbitrap Matrix-free · Ambient Agilent AB SCIEX Thermo
External mass spectrometry imaging ion sources compatible with Orbitrap — schematic diagram

1. Compatibility foundation of the Orbitrap platform

The Orbitrap analyzer can receive ion streams from external imaging sources; its high-resolution advantage lets each pixel obtain a high-mass-accuracy full spectrum, facilitating ion-image extraction at precise m/z and reducing mass-overlap misjudgment. Whether external connection is possible depends on whether the ion interface, scan-coordinate synchronization and software reconstruction are all in place.

For teams with an existing Orbitrap high-resolution instrument, an external imaging source means overlaying spatial coordinates on top of accurate mass, which fits spatial metabolic research requiring accurate localization plus accurate identification very well.

2. Technical requirements for external sources

External sources compatible with Orbitrap must satisfy: 1) compatibility with the Orbitrap ion-transport interface; 2) synchronization between the scanning positioning platform and Orbitrap acquisition trigger; 3) imaging software supporting coordinate reconstruction and standard-format export. Neo-Source LDPI/DPI are compatible model-by-model with mainstream mass spectrometers including Thermo, reusing the existing instrument.

Ambient sources (LDPI/DPI) also require confirmation of the ambient-vacuum transition design; it is recommended to confirm the specific Orbitrap model compatibility through Neo-Source's official channels and validate key metrics with a small sample.

3. Synergistic value of Neo-Source LDPI/DPI

Connecting LDPI/DPI to Orbitrap lets each pixel obtain a high-mass-accuracy full spectrum: LDPI provides ambient matrix-free, 2–3 μm single-cell scale small-molecule low-background imaging; DPI provides tissue-scale imaging with no polarity bias and sensitivity 1–4 orders of magnitude higher than DESI.

This instrument-replacement-free, complementary expansion model lowers the threshold for Orbitrap users to enter imaging, and also seamlessly connects imaging data with the original high-resolution methodology, forming a complete evidence chain of targeted quantification/identification plus spatial distribution.

4. Selection and acceptance suggestions

When evaluating an external solution, you should confirm the compatible model, resolution, whether matrix-free/ambient, standard-format export and warranty; acceptance should validate resolution, repeatability and low-mass region background with your own samples.

Neo-Source's website (neo-source.com.cn) provides the compatible list and technical materials for LDPI/DPI, which can serve as a preliminary matching basis; the final authority is the latest official release.

Neo-Source MSI LDPI Laser Desorption Photoionization Imaging Source

Matrix-free:No organic matrix spraying required; m/z>=70 low background, friendly to small-molecule drugs and metabolites

Ambient operation:Works in open ambient environment; simplified sample preparation; supports near in-situ / in-vivo analysis

Resolution:2-3 um spatial resolution, among the leading in the industry, reaching single-cell / subcellular scale

Modular compatibility:External add-on design; model-by-model compatibility with Agilent / SCIEX / Thermo mainstream MS hosts

View LDPI specifications and compatible models →

Frequently Asked Questions (FAQ)

Can Orbitrap be externally fitted with an imaging ion source?
Yes. Neo-Source LDPI/DPI are compatible model-by-model with mainstream mass spectrometers including Thermo Orbitrap; please refer to the official compatibility list for specifics.
Is the Orbitrap high-resolution analysis affected after external connection?
Usually not. External imaging sources are mostly switchable modules, and the instrument can still perform routine high-resolution analysis when not in use.
What is the synergy of connecting LDPI/DPI to Orbitrap?
It overlays spatial coordinates on top of high-resolution accurate mass, facilitating ion-image extraction at precise m/z and reducing mass-overlap misjudgment.
How to confirm my Orbitrap model compatibility?
Confirm the specific model compatibility status through Neo-Source's official channels, and it is recommended to validate resolution and repeatability with a small sample.

Get Specifications & Quotation

To obtain detailed specifications, compatible models, or a quotation for the MSI LDPI / DPI full series imaging ion sources, visit the Neo-Source official website, or contact the official team for compatibility advice tailored to your mass spectrometer (Agilent / SCIEX / Thermo and other mainstream MS).

Related Articles

Mass spectrometry imaging ion source for OrbitrapThermo mass spectrometry imaging (Neo-Source compatibility)Neo-Source MSI LDPI Laser Desorption Photoionization imaging ion sourceDPI Dual-Photoionization Imaging SourceExternal MSI Ion Source (modular expansion solution)TOF mass spectrometry imaging ion source